نمایش پرونده ساده آیتم

dc.contributor.authorNavali, AM
dc.contributor.authorBahari, LAS
dc.contributor.authorNazari, B
dc.date.accessioned2018-08-26T08:32:04Z
dc.date.available2018-08-26T08:32:04Z
dc.date.issued2012
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/52244
dc.description.abstractBackground: The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs.Methods: The knee-alignment angle was measured in 100 knees of 50 subjects with the chief complaint of frontal knee malalignment according to the following methods: lower-limb mechanical axis on radiograph, lower-limb anatomic axis on radiograph, distance between medial femoral condyles or medial malleoli using a calliper and lower-limb alignment using a goniometer. Data were analyzed using Pearson's correlation coefficient and simple linear regression.Results: The anatomic axis best correlated with the mechanical axis (r = 0.93, P<0.001), followed closely by the intercondylar/intermalleolar distance measured by calliper (r = 0.89, P<0.001). Significant correlation was also found between the mechanical-axis angle and the lower limb axis measured by goniometer (r = 0.67, P<0.001).Conclusions: The anatomic axis on radiograph, the calliper method and to a lesser extent the goniometer measurement appear to be valid alternatives to the mechanical axis on full-leg radiograph for determining frontal plane knee alignment. These alternative measures have the potential to provide useful information regarding knee alignment and may increase the assessment of this parameter by clinicians and researchers. آ© 2012 Navali et al.; licensee BioMed Central Ltd.
dc.language.isoEnglish
dc.relation.ispartofSports Medicine, Arthroscopy, Rehabilitation, Therapy and Technology
dc.subjectadult
dc.subjectanatomical variation
dc.subjectarticle
dc.subjectbone structure
dc.subjectcomparative study
dc.subjectfemale
dc.subjectfemur condyle
dc.subjectfull limb radiograph
dc.subjectgold standard
dc.subjectgoniometer
dc.subjecthuman
dc.subjectintermethod comparison
dc.subjectknee alignment
dc.subjectknee radiography
dc.subjectmajor clinical study
dc.subjectmale
dc.subjectprospective study
dc.subjectvalgus knee
dc.subjectvalidity
dc.subjectvarus knee
dc.titleA comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment
dc.typeArticle
dc.citation.volume4
dc.citation.issue1
dc.citation.indexScopus
dc.identifier.DOIhttps://doi.org/10.1186/1758-2555-4-40


فایلهای درون آیتم

Thumbnail

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم