Show simple item record

dc.contributor.authorNasirizadeh, N
dc.contributor.authorZare, HR
dc.contributor.authorPournaghi-Azar, MH
dc.contributor.authorHejazi, MS
dc.date.accessioned2018-08-26T08:08:57Z
dc.date.available2018-08-26T08:08:57Z
dc.date.issued2011
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/50393
dc.description.abstractFor the detection of DNA hybridization, a new electrochemical biosensor was developed on the basis of the interaction of hematoxylin with 20-mer deoxyoligonucleotides (from human papilloma virus, HPV). The study was performed based on the interaction of hematoxylin with an alkanethiol DNA probe self-assembled gold electrode (ss-DNA/AuE) and its hybridization form (ds-DNA/AuE). The optimum conditions were found for the immobilization of HPV probe on the gold electrode (AuE) surface and its hybridization with the target DNA. Electrochemical detection of the self-assembled DNA and the hybridization process were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over the potential range where the accumulated hematoxylin at the modified electrode was electroactive. Observing a remarkable difference between the voltammetric signals of the hematoxylin obtained from different hybridization samples (non-complementary, mismatch and complementary DNAs), we confirmed the potential of the developed biosensor in detecting and discriminating the target complementary DNA from non-complementary and mismatch oligonucleotides. Under optimum conditions, the electrochemical signal had a linear relationship with the concentration of the target DNA ranging from 12.5 nM to 350.0 nM, and the detection limit was 3.8 nM. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
dc.language.isoEnglish
dc.relation.ispartofBIOSENSORS & BIOELECTRONICS
dc.subjectDNA biosensor
dc.subjectHybridization indicators
dc.subjectDifferential pulse voltammetry
dc.subjectHematoxylin
dc.subjectHuman papilloma virus
dc.titleIntroduction of hematoxylin as an electroactive label for DNA biosensors and its employment in detection of target DNA sequence and single-base mismatch in human papilloma virus corresponding to oligonucleotide
dc.typeArticle
dc.citation.volume26
dc.citation.issue5
dc.citation.spage2638
dc.citation.epage2644
dc.citation.indexWeb of science
dc.identifier.DOIhttps://doi.org/10.1016/j.bios.2010.11.026


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record