Show simple item record

dc.contributor.authorAlthanyan, MS
dc.contributor.authorAssi, KH
dc.contributor.authorClark, BJ
dc.contributor.authorHanaee, J
dc.date.accessioned2018-08-26T08:08:08Z
dc.date.available2018-08-26T08:08:08Z
dc.date.issued2011
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/50290
dc.description.abstractA robust and sensitive microemulsion HPLC (MELC) method using oil-in-water microemulsion mobile phase was developed and used for the determination of terbutaline in Bricanyl (R) Turbuhaler. The applicability of microemulsion as an eluent for reversed phase HPLC was examined. In addition, the effect of operating parameters on the separation behaviour was studied. The samples were injected into C18 Spherisorb (250 mm x 4.6 mm x 5 mu m) columns at 25 degrees C using a flow rate of 1 ml/min. The mobile phase was 95.5% aqueous orthophosphate buffer (adjusted to pH 3 with orthophosphoric acid), 0.5% ethyl acetate, 1.5% Brij35, and 2.5% 1-butanol, all w/w. The terbutaline peak was detected by fluorescence, using excitation and emission wavelengths of 267 and 313 nm, respectively. The accuracy of method was >99% and the calibration curve was linear (r(2) = 0.99). The limit of detection (LOD) and limit of quantitation (LOQ) were 8 mu g/L and 26 mu g/L, respectively. The intra-day and inter-day precisions (in term of % coefficient of variation) were <1.46% and <0.97%, respectively. The influence of the composition of the microemulsion system was also studied and the method was found to be robust with respect to some changes of the microemulsion components. The microemulsion HPLC method has been applied to determine the content of the emitted dose and the fine particle dose of terbutaline in a Bricanyl (R) Turbuhaler. (C) 2011 Elsevier B.V. All rights reserved.
dc.language.isoEnglish
dc.relation.ispartofJOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
dc.subjectMicroemulsion
dc.subjectHPLC
dc.subjectMELC
dc.subjectDetermination
dc.subjectValidation
dc.subjectTerbutaline
dc.titleMicroemulsion high performance liquid chromatography (MELC) method for the determination of terbutaline in pharmaceutical preparation
dc.typeArticle
dc.citation.volume55
dc.citation.issue3
dc.citation.spage397
dc.citation.epage402
dc.citation.indexWeb of science
dc.identifier.DOIhttps://doi.org/10.1016/j.jpba.2011.01.027


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record