Show simple item record

dc.contributor.authorShahi, S
dc.contributor.authorMokhtari, H
dc.contributor.authorRahimi, S
dc.contributor.authorShiezadeh, V
dc.contributor.authorAshasi, H
dc.contributor.authorAbdolrahimi, M
dc.contributor.authorForoughreyhani, M
dc.date.accessioned2018-08-26T08:05:27Z
dc.date.available2018-08-26T08:05:27Z
dc.date.issued2012
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/49821
dc.description.abstractAim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner described. In autoclave groups, 72 files from each file type were evenly distributed into 2 groups. Files were used for a cycle of sterilization without the use of files for root canal preparation. Nine new unused files from each file type were used as controls. Then the instruments were sent for corrosion assessment. Mann-Whitney U and Wilcoxon tests were used for independent and dependent groups, respectively. Results: Statistical analysis indicated that there were significant differences in corrosion resistance of files associated with working and autoclave groups between RaCe and Mtwo file types (p<0.001). Conclusions: Corrosion resistance of #25, #30, and #35 Mtwo files is significantly higher than that in RaCe files with similar sizes.
dc.language.isoEnglish
dc.relation.ispartofMEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL
dc.subjectCorrosion
dc.subjectNiTi instruments
dc.subjectautoclave
dc.subjectRaCe
dc.subjectMtwo
dc.titleElectrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization
dc.typeArticle
dc.citation.volume17
dc.citation.issue2
dc.citation.spageE331
dc.citation.epageE336
dc.citation.indexWeb of science
dc.identifier.DOIhttps://doi.org/10.4317/medoral.17413


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record