dc.contributor.author | Rashid, RJ | |
dc.contributor.author | Tarzemani, MK | |
dc.contributor.author | Mohtasham, MA | |
dc.contributor.author | Zomorrodi, A | |
dc.contributor.author | Kakaei, F | |
dc.contributor.author | Jalili, J | |
dc.contributor.author | Habibzadeh, A | |
dc.date.accessioned | 2018-08-26T07:56:16Z | |
dc.date.available | 2018-08-26T07:56:16Z | |
dc.date.issued | 2014 | |
dc.identifier.uri | http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/48763 | |
dc.description.abstract | Introduction: Multidetector-row computed tomography (MDCT) angiography is a reliable technique in preoperative renal anatomy evaluation in live renal donors. Objectives: To investigate the accuracy of early arterial phase findings and compares them with intraoperative findings. Methods: In this prospective study, 100 potential live donors undergoing preoperative MDCT and nephrectomy during 2010-2013 were included. The examination was performed with a 64-detector scanner including early arterial and venous phase. MDCT angiography started by bolus tracking and venous phase was acquired 9 s after arterial phase. Anatomical findings and vein and artery attenuation values were recorded and arterial phase findings were compared with intraoperative findings. Results: All anatomical findings reported by MDCT in early arterial phase were confirmed by intraoperative findings with sensitivity of 100%. Right renal vein was supernumerary in 17 cases and left renal vein was circumaortic in 3 and retroaortic in 5 cases. Renal arteries had early branching in 13, two arteries in 12 and accessory in 8 cases. Vein and artery attenuation values had significant difference between early arterial and venous phase (p<0.001). Conclusion: Early arterial phase has similar results to venous phase in preoperative evaluation and intraoperative findings and could be used alone to reduce radiation dose. | |
dc.language.iso | English | |
dc.relation.ispartof | RENAL FAILURE | |
dc.subject | Angiography | |
dc.subject | live kidney | |
dc.subject | multidetector computed tomography | |
dc.subject | nephrectomy | |
dc.subject | renal anatomy | |
dc.title | Diagnostic accuracy of 64-MDCT angiography in the preoperative evaluation of renal vessels and compared with laparotomy findings in living donor kidney | |
dc.type | Article | |
dc.citation.volume | 36 | |
dc.citation.issue | 3 | |
dc.citation.spage | 327 | |
dc.citation.epage | 331 | |
dc.citation.index | Web of science | |
dc.identifier.DOI | https://doi.org/10.3109/0886022X.2013.862768 | |