dc.description.abstractBackground: Persistent angular deformities around the knee can lead to growth-plate damage in childhood and osteoarthritis in adulthood. The treatment options include osteotomy and hemiepiphysiodesis. Tension-band plate hemiepiphysiodesis with 8-plate is an effective way to correct these deformities. However, its high cost makes it less available in many countries. In the present series, we have used 3.5 mm reconstruction plates for tension-band temporary hemiepiphysiodesis. Methods: Twenty-one patients with bilateral angular deformities of the knee (42 extremities) underwent temporary hemiepiphysiodesis with 3.5 mm reconstruction plates. The diagnosis, BMI, weight, amount of correction of the deformity age, and device failure were analyzed. The mean follow-up period after plate removal was 17 months (ranging from 8 to 24 mo). Results: The mean age of the patients was 10 years and 3 months (+/- 2 y and 10 mo). Complete correction of the deformities was achieved in 86% of patients. Of the 58 plate and screw constructs, 10% had screw breakage. Patients with genu valgum had 2 screw failures (6.25%), but in the genu varum group there were 4 screw failures (40%). Of the 3 patients who did not have complete correction of the deformities, 2 had mucopolysaccharidosis and 1 was nearing skeletal maturity (16 y old). The age of the patient, body weight, BMI, and degrees of angulation did not have any statistically significant correlation with the screw failure. Screw failures in female patients were more common than in male patients. All implant failures occurred in idiopathic patients. Conclusions: The efficacy of 3.5 mm reconstruction plates for temporary hemiepiphysiodesis around the knee is similar to that of 8-plates. However, the reconstruction plates have a lower cost and are easily available. Noncanulated 3.5 or 4.5 mm cortical screws seem to be superior to 4 mm noncanulated cancellous screws.
dc.language.isoEnglish
dc.relation.ispartofJOURNAL OF PEDIATRIC ORTHOPAEDICS
dc.subjectgenu varum
dc.subjectgenu valgum
dc.subjectangular deformity
dc.subject8-plate
dc.subjectstaple
dc.subjecthemiepiphysiodesis
dc.subjectscrew breakage
dc.subjectreconstruction plate
dc.titleThe Efficacy and Complications of 2-Hole 3.5 mm Reconstruction Plates and 4 mm Noncanulated Cancellous Screws for Temporary Hemiepiphysiodesis Around the Knee
dc.typeArticle
dc.citation.volume34
dc.citation.issue4
dc.citation.spage462
dc.citation.epage466
dc.citation.indexWeb of science
dc.citation.URLhttps://journals.lww.com/pedorthopaedics/Abstract/2014/06000/The_Efficacy_and_Complications_of_2_Hole_3_5_mm.18.aspx