Show simple item record

dc.contributor.authorKhalilzadeh, B
dc.contributor.authorShadjou, N
dc.contributor.authorAfsharan, H
dc.contributor.authorEskandani, M
dc.contributor.authorCharoudeh, HN
dc.contributor.authorRashidi, MR
dc.date.accessioned2018-08-26T07:40:59Z
dc.date.available2018-08-26T07:40:59Z
dc.date.issued2016
dc.identifier10.15171/bi.2016.20
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/47341
dc.description.abstractIntroduction: Growing demands for ultrasensitive biosensing have led to the development of numerous signal amplification strategies. In this report, a novel electrochemiluminescence (ECL) method was developed for the detection and determination of caspase-3 activity based on reduced graphene oxide sheets decorated by gold nanoparticles as signal amplification element and horseradish peroxidase enzyme (HRP) as ECL intensity enhancing agent. Methods: The ECL intensity of the luminol was improved by using the streptavidin coated magnetic beads and HRP in the presence of hydrogen peroxide. The cleavage behavior of caspase-3 was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using biotinylated peptide (DEVD containing peptide) which was coated on reduced graphene oxide decorated with gold nanoparticle. The surface modification of graphene oxide was successfully confirmed by FTIR, UV-vis and x-ray spectroscopy. Results: ECL based biosensor showed that the linear dynamic range (LDR) and the lower limit of quantification (LLOQ) were 0.5-100 and 0.5 femtomolar (fM), respectively. Finally, the performance of the engineered peptide based biosensor was validated in the A549 cell line as real samples. Conclusion: The prepared peptide based biosensor could be considered as an excellent candidate for early detection of apoptosis, cell turnover, and cancer related diseases.
dc.language.isoEnglish
dc.relation.ispartofBIOIMPACTS
dc.subjectApoptosis
dc.subjectCaspase-3
dc.subjectDEVD-peptide
dc.subjectElectrochemiluminescence
dc.subjectGold nanoparticle
dc.subjectReduced graphene oxide
dc.titleReduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
dc.typeArticle
dc.citation.volume6
dc.citation.issue3
dc.citation.spage135
dc.citation.epage147
dc.citation.indexWeb of science
dc.identifier.DOIhttps://doi.org/10.15171/bi.2016.20


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record