dc.description.abstractObjectives: To assess the diagnostic accuracy of ultrasonographic optic nerve sheath diameter (ONSD) measurement and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure (ICP). Patients and methods: A total 60 patients with (cases, n = 30) and without (controls, n = 30) acute clinical and computed tomographic findings of elevated ICP due to intracranial mass/hemorrhage were recruited from a teaching hospital. The mean binocular and maximum ultrasonographic ONSDs, as well as the mean binocular Doppler ultrasound waveform indices of the ophthalmic arteries including pulsatility index (PI), resistive index (RI), end-systolic velocity (ESV), peak systolic velocity (PSV) and end-diastolic velocity (EDV) were compared between the two groups. Results: Compared to controls, the case group had significantly higher mean binocular ONSD (5.48 +/- 0.52 mm vs. 4.09 +/- 0.22 mm, p < 0.001), maximum ONSD (5.63 +/- 0.55 mm vs. 4.16 +/- 0.23 mm, p < 0.001), mean PI (1.53 0.16 vs. 1.45 0.20, p = 0.01), and mean RI (0.76 +/- 0.07 vs. 0.73 +/- 0.04, p = 0.01). The mean EDV, in contrast, was significantly higher in controls (8.55v3.09 m/s vs. 7.17 +/- 2.61 m/s, p = 0.01). The two groups were comparable for the mean PSV (30.73 +/- 7.93 m/s in cases vs. 32.27 +/- 10.39 m/s in controls, p = 0.36). Among the mentioned variables, the mean binocular ONSD was the most accurate parameter in detecting elevated ICP (sensitivity and specificity of 100%, cut-off point = 4.53 mm). The Doppler indices were only moderately accurate (sensitivity: 56.7- 60%, specificity: 63.3- 76.7%). Conclusion: While the ultrasonographic mean binocular ONSD (>4.53 mm) was completely accurate in detecting elevated ICP, color Doppler indices of the ophthalmic arteries were of limited value. (C) 2015 Elsevier B.V. All rights reserved.
dc.language.isoEnglish
dc.relation.ispartofCLINICAL NEUROLOGY AND NEUROSURGERY
dc.subjectUltrasonography
dc.subjectColor Doppler ultrasound
dc.subjectOptic nerve sheath diameter
dc.subjectOphthalmic artery
dc.subjectIntracranial pressure
dc.titleThe diagnostic performance of ultrasonographic optic nerve sheath diameter and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure
dc.typeArticle
dc.citation.volume141
dc.citation.spage82
dc.citation.epage88
dc.citation.indexWeb of science
dc.identifier.DOIhttps://doi.org/10.1016/j.clineuro.2015.12.007


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record