Show simple item record

dc.contributor.authorHashemzadeh, S
dc.contributor.authorMehrafsa, B
dc.contributor.authorKakaei, F
dc.contributor.authorJavadrashid, R
dc.contributor.authorGolshan, R
dc.contributor.authorSeifar, F
dc.contributor.authorHajibonabi, F
dc.contributor.authorKhorami, FS
dc.date.accessioned2018-08-26T07:11:33Z
dc.date.available2018-08-26T07:11:33Z
dc.date.issued2018
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/44364
dc.description.abstractPeriampullary tumors are highly malignant masses with poor prognosis. Surgical resection is the only treatment for patients with this disease. The preoperative evaluation of masses is essential to determine the tumor resectability and vascular invasion. The aim of this study was to determine the diagnostic accuracy of 64-slice multi-detector computed tomography (MDCT) in detecting the resectability of periampullary masses. A cross-sectional study was conducted on patients with a definite diagnosis of periampullary cancer. All the participants underwent an MDCT scan before the surgical pancreaticoduodenectomy. The preoperative results were compared to the intraoperative findings and the diagnostic accuracy was determined based on the sensitivity and specificity of the MDCT. From June 2015 until June 2016, 32 patients with periampullary carcinoma were enrolled in the study. Of 32 masses, one of them considered nonresectable because of the gross vascular invasion in th CT images. After the operation, the overall resectability rate was 81.3%. The sensitivity and specificity of MDCT for tumor resectability was 100% and 16.7%, respectively, with an overall accuracy of 84.4%. To sum up, MDCT had high sensitivity but low specificity in the preoperative evaluation of preampullary carcinomas. The low specificity resulted from the low accuracy of the CT scan in detecting vascular involvement.
dc.language.isoEnglish
dc.relation.ispartofJOURNAL OF CLINICAL MEDICINE
dc.subjectmulti-detector computed tomography
dc.subjectdiagnosis
dc.subjectperiampullary carcinoma
dc.subjectpancreas
dc.titleDiagnostic Accuracy of a 64-Slice Multi-Detector CT Scan in the Preoperative Evaluation of Periampullary Neoplasms
dc.typeArticle
dc.citation.volume7
dc.citation.issue5
dc.citation.indexWeb of science
dc.identifier.DOIhttps://doi.org/10.3390/jcm7050091


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record