نمایش پرونده ساده آیتم

dc.contributor.authorOskoee, SS
dc.contributor.authorOskoee, PA
dc.contributor.authorNavimipour, EJ
dc.contributor.authorShahi, S
dc.date.accessioned2018-08-26T06:33:31Z
dc.date.available2018-08-26T06:33:31Z
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/43749
dc.description.abstractMany endodontically-treated teeth require quick, simple, low-cost restorations. This study evaluated the effect of horizontal pins and flowable composites on the fracture resistance of endodontically-treated maxillary premolars directly restored with resin composite. In this in vitro study, 64 intact human maxillary premolars, extracted for orthodontic reasons, were randomly divided into four groups of 16. Standard access cavities were prepared in such a way that the buccal cusp had a buccolingual thickness of 3 mm measured at the height of contour. The palatal cusp was reduced to 1.5 mm coronal to CEJ. The specimens were prepared as follows: Group 1: resin composite restoration without horizontal self-threading pins or flowable composite (control group). Group 2: resin composite restoration without horizontal self-threading pins but with a 2 mm thickness of the flowable composite. Group 3: resin composite restoration with two horizontal self-threading pins in the buccal cusp but without flowable composite. Group 4: resin composite restoration with two horizontal self-threading pins in the buccal cusp and flowable composite with a thickness of 2 mm. Subsequent to thermocycling, all specimens were loaded to failure. The data were analyzed using a two-factor ANOVA test (alpha = 0.05). The maximum mean of fracture resistance was in Group 1 (632.86 +/- 119.46 N), and the minimum value was related to Group 3 (533.49 +/- 168.07 N). There was not a statistically significant difference between the groups (p > 0.05).Neither horizontal pin placement nor flowable composite had a significant effect on increasing the fracture resistance of endodontically-treated maxillary premolars restored with composite.
dc.language.isoEnglish
dc.relation.ispartofOperative dentistry
dc.subjectAcid Etching, Dental
dc.subjectBicuspid
dc.subjectComposite Resins
dc.subjectDental Cavity Preparation
dc.subjectDental Enamel
dc.subjectDental Pins
dc.subjectDental Restoration, Permanent
dc.subjectDentin
dc.subjectDentin-Bonding Agents
dc.subjectHumans
dc.subjectMaxilla
dc.subjectRoot Canal Therapy
dc.subjectStress, Mechanical
dc.subjectTooth Fractures
dc.subjectTooth, Nonvital
dc.titleIn vitro fracture resistance of endodontically-treated maxillary premolars.
dc.typearticle
dc.citation.volume32
dc.citation.issue5
dc.citation.spage510
dc.citation.epage4
dc.citation.indexPubmed
dc.identifier.DOIhttps://doi.org/10.2341/06-149


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم