dc.contributor.author | Hejazi, MS | |
dc.contributor.author | Pournaghi-Azar, MH | |
dc.contributor.author | Alipour, E | |
dc.contributor.author | Karimi, F | |
dc.date.accessioned | 2018-08-26T06:33:23Z | |
dc.date.available | 2018-08-26T06:33:23Z | |
dc.date.issued | 2008 | |
dc.identifier.uri | http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/43702 | |
dc.description.abstract | Construction, electrochemically biosensing and discrimination of recombinant pEThIL-2 plasmid, with 5839bp size, on the basis of interleukine-2 (IL-2) DNA insert are described. Plasmid pEThIL-2 was constructed by PCR amplification of IL-2 encoding DNA and subcloning into pET21a(+) vector using BamHI and SacI sites. The recombinant pEThIL-2 plasmid was detected with a label-free DNA hybridization biosensor using a non-inosine substituted probe. The proposed sensor was made up by immobilization of a 20-mer antisense single strand oligonucleotide (chIL-2) related to the human interleukine-2 gene on the pencil graphite electrode (PGE) as a probe and then the sensing of recombinant pEThIL-2 plasmid was conducted by anodic differential pulse voltammetry (ADPV) based on guanine oxidation signal. Selectivity of the detection was assessed with pET21a(+) non-complementary plasmid, with 5443bp size, lacking IL-2 encoding DNA. Different factors such as electrode activation conditions and washing strategy were tested in order to eliminate the nonspecific adsorption of pET21a(+). We have found that the PGE activation for 300s produces a condition in which desorption of nonspecifically adsorbed plasmids from the electrode surface can be achieved by 300s washing of the electrode in 20mM Tris-HCl buffer solution (pH 7.0) containing 20mM NaCl. Diagnostic performance of the biosensor is described and the detection limit is found to be 10.31pg/microL. | |
dc.language.iso | English | |
dc.relation.ispartof | Biosensors & bioelectronics | |
dc.subject | Biosensing Techniques | |
dc.subject | DNA Transposable Elements | |
dc.subject | Electrochemistry | |
dc.subject | Equipment Design | |
dc.subject | Equipment Failure Analysis | |
dc.subject | Interleukin-2 | |
dc.subject | Oligonucleotide Array Sequence Analysis | |
dc.subject | Plasmids | |
dc.subject | Recombination, Genetic | |
dc.subject | Sensitivity and Specificity | |
dc.title | Construction, electrochemically biosensing and discrimination of recombinant plasmid (pEThIL-2) on the basis of interleukine-2 DNA insert. | |
dc.type | article | |
dc.citation.volume | 23 | |
dc.citation.issue | 11 | |
dc.citation.spage | 1588 | |
dc.citation.epage | 94 | |
dc.citation.index | Pubmed | |
dc.identifier.DOI | https://doi.org/10.1016/j.bios.2008.01.021 | |