dc.description.abstractThe Cardiac Output (CO), Filling Time (FT) and Myocardial Performance Index (MPI) derived optimal atrioventricular delay (AVD), were compared and systolic and diastolic performance at every optimal AVD were analyzed. Thirty-two patients with implanted DDD pacemaker were investigated from implantation time to 6 months following PM implantation, in Cardiovascular Research Center of Tabriz University of Medical Sciences. The evaluation was performed during AV sequential pacing with different programmed AVDS ranged from 100 to 200 msec by steps of 20-30 msec. At every AVD, the following parameters were measured: FT, mitral VTI, ET, aortic VTI, ICT and IRT. CO and FT derived optimal AVDs were significantly different (146 +/- 37 and 126 +/- 35 msec, respectively), but their difference with MPI derived optimal AVDs was not significant (130 +/- 28 msec). ICT/ET was similar at CO, FT and MPI derived optimal AVD (0.24 +/- 0.10, 0.22 +/- 0.05 and 0.20 +/- 0.07, respectively). IRT/ET ratio was similar at CO, FT and MPI derived optimal AVDs (0.46 +/- 0.14, 0.45 +/- 0.10 and 0.42 +/- 0.10, respectively). Different methods indicate different optimal AVDs. However analysis of systolic and diastolic performance shows that different AVDs result in similar systolic or diastolic performance. At MPI optimized AVD, a high CO combined with the most advantageous conditions of both isovolumic contraction and relaxation phases is achieved.
dc.language.isoEnglish
dc.relation.ispartofPakistan journal of biological sciences : PJBS
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectAged, 80 and over
dc.subjectAtrioventricular Node
dc.subjectCardiac Output
dc.subjectCardiac Pacing, Artificial
dc.subjectCross-Sectional Studies
dc.subjectDiastole
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectPacemaker, Artificial
dc.subjectYoung Adult
dc.titleAtrioventricular delays, cardiac output and diastolic function in patients with implanted dual chamber pacing and sensing pacemakers.
dc.typearticle
dc.citation.volume11
dc.citation.issue20
dc.citation.spage2407
dc.citation.epage12
dc.citation.indexPubmed


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم