Show simple item record

dc.contributor.authorAzar, ZF
dc.contributor.authorHakimi, P
dc.contributor.authorGhojazadeh, M
dc.contributor.authorGhatresamani, F
dc.date.accessioned2018-08-26T06:14:13Z
dc.date.available2018-08-26T06:14:13Z
dc.date.issued2011
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/42989
dc.description.abstractChanges of cervical ultrasonographic physical parameters and their association with outcome of cerclage have not been fully elucidated. This study aimed at evaluating association between ultrasonographic physical cervical shapes before and after McDonald cerclage with the length of pregnancy. Cervical length, width and funneling rate were assessed by transvaginal ultrasonography before and after the procedure. Mean pre-cerclage cervical length, width and funneling rate were 29.28 +/- 5.54, 19.92 +/- 10.30 mm and 12.90 +/- 18.87%, respectively. The mean post-cerclage cervical length, diameter and funneling rate were 31.68 +/- 4.21, 9.78 +/- 13.86 and 4.32 +/- 10.89%, respectively (p < 0.001 for all pre- and post-cerclage changes). The mean post-cerclage duration of pregnancy was 19.78 +/- 5.94 weeks. There were significant direct correlations between the pre-and post-cerclage cervical lengths with pregnancy duration (r = 0.24, p = 0.04 and r = 0.44, p < 0.001, respectively). There were significant indirect correlations between the pre- and post-cerclage funneling rate with pregnancy duration (r = -0.30, p = 0.01 and r = -0.20, p = 0.01, respectively). Similar correlations were not significant for the cervical widths. This study showed that the pre- and post-cerclage ultrasonographically determined cervical length and funneling are good predictors of pregnancy duration.
dc.language.isoEnglish
dc.relation.ispartofPakistan journal of biological sciences : PJBS
dc.subjectAdolescent
dc.subjectAdult
dc.subjectCerclage, Cervical
dc.subjectCervix Uteri
dc.subjectCohort Studies
dc.subjectFemale
dc.subjectHumans
dc.subjectInfant, Newborn
dc.subjectMiddle Aged
dc.subjectPregnancy
dc.subjectPregnancy Outcome
dc.subjectPremature Birth
dc.subjectTime Factors
dc.subjectUltrasonography
dc.subjectUterine Cervical Incompetence
dc.subjectYoung Adult
dc.titlePre- and post-McDonald cerclage cervical length, width and funneling rate and their association with duration of pregnancy.
dc.typearticle
dc.citation.volume14
dc.citation.issue8
dc.citation.spage502
dc.citation.epage6
dc.citation.indexPubmed


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record