• English
    • Persian
    • English
    • Persian
  • English 
    • English
    • Persian
    • English
    • Persian
  • Login
View Item 
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
  •   KR-TBZMED Home
  • TBZMED Published Academics Works
  • Published Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Detection of foreign bodies by spiral computed tomography and cone beam computed tomography in maxillofacial regions.

Thumbnail
Date
2014
Author
Kaviani, F
Javad Rashid, R
Shahmoradi, Z
Gholamian, M
Metadata
Show full item record
Abstract
Background and aims. The imaging techniques commonly used for foreign body detection include plain radiography, xeroradiography, computed tomography (CT) scans, magnetic resonance imaging (MRI) and ultrasonography. The aim of the present study was to compare cone-beam computed tomography (CBCT) with conventional CT scan in determination of the exact location of a foreign body in the maxillofacial area in vitro. Materials and methods. In this descriptive study, seven different materials were selected as foreign bodies with dimensions of approximately 2 mm, 1 mm, and 0.5 mm. These materials consisted of metal, glass, wood, stone, plastic, graphite and tooth. These foreign bodies were placed in a sheep head between the corpus of the mandible and muscle, in the tongue and in an air space. One conventional CT scan and two CBCT scans were made on the models. Results. Tooth, metal, stone and glass foreign bodies were seen clearly on CT and CBCT scans made by NewTom at the smallest size in air. However, CBCT scan by NewTom was a more effective technique for visualization of foreign bodies in air compared to conventional CT. Foreign bodies measuring 0.5 mm made of metal, stone, glass, graphite and teeth were detected by all devices in muscle tissue and adjacent bone. Conclusion. According to the results, CBCT scans of NewTom and Planmeca are appropriate tools for detecting foreign bodies with relative high density in the maxillofacial area.
URI
http://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/41340
Collections
  • Published Articles

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of KR-TBZMEDCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Knowledge repository of Tabriz University of Medical Sciences using DSpace software copyright © 2018  HTMLMAP
Contact Us | Send Feedback
Theme by 
Atmire NV