نمایش پرونده ساده آیتم

dc.contributor.authorNavimipour, EJ
dc.contributor.authorFirouzmandi, M
dc.contributor.authorMirhashemi, FS
dc.date.accessioned2018-08-26T05:43:57Z
dc.date.available2018-08-26T05:43:57Z
dc.date.issued2015
dc.identifier.urihttp://dspace.tbzmed.ac.ir:8080/xmlui/handle/123456789/40792
dc.description.abstractThis study evaluated the effect of three methods of glass fiber insertion on stress distribution pattern and cusp movement of the root-filled maxillary premolars using finite element method (FEM) analysis.A three-dimensional (3 D) FEM model of a sound upper premolar tooth and four models of root-filled upper premolars with mesiocclusodistal (MOD) cavities were molded and restored with: (1) Composite resin only (NF); (2) Composite resin along with a ribbon of glass fiber placed in the occlusal third (OF); (3) Composite resin along with a ribbon of glass fiber placed circumferentially in the cervical third (CF), and (4) Composite resin along with occlusal and circumferential fibers (OCF). A static vertical load was applied to calculate the stress distributions. Structural analysis program by Solidworks were used for FEM analysis. Von-Mises stress values and cusp movements induced by occlusal loading were evaluated.Maximum Von-Mises stress of enamel occurred in sound tooth, followed by NF, CF, OF and OCF. Maximum Von-Mises stress of dentin occurred in sound tooth, followed by OF, OCF, CF and NF. Stress distribution patterns of OF and OCF were similar. Maximum overall stress values were concentrated in NF. Although stress distribution patterns of NF and CF were found as similar, CF showed lower stress values. Palatal cusp movement was more than buccal cusp in all of the models.The results of our study indicated that while the circumferential fiber had little effect on overall stress concentration, it provided a more favorable stress distribution pattern in cervical region. The occlusal fiber reduced the average stress in the entire structure but did not reduce cuspal movement.Incorporating glass fiber in composite restorations may alter the stress state within the structure depending on fiber position.
dc.language.isoEnglish
dc.relation.ispartofThe journal of contemporary dental practice
dc.subjectBicuspid
dc.subjectBiomechanical Phenomena
dc.subjectComposite Resins
dc.subjectDental Enamel
dc.subjectDental Materials
dc.subjectDental Pulp Cavity
dc.subjectDental Restoration, Permanent
dc.subjectDentin
dc.subjectFinite Element Analysis
dc.subjectGlass
dc.subjectHumans
dc.subjectImaging, Three-Dimensional
dc.subjectMaxilla
dc.subjectStress, Mechanical
dc.subjectTooth Cervix
dc.subjectTooth Crown
dc.subjectTooth, Nonvital
dc.titleFinite Element Analysis of the Endodontically-treated Maxillary Premolars restored with Composite Resin along with Glass Fiber Insertion in Various Positions.
dc.typearticle
dc.citation.volume16
dc.citation.issue4
dc.citation.spage284
dc.citation.epage90
dc.citation.indexPubmed


فایلهای درون آیتم

فایلهاسایزفرمتنمایش

هیچ فایل مرتبطی وجود ندارد

این آیتم در مجموعه های زیر مشاهده می شود

نمایش پرونده ساده آیتم